| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4435.0185 is a 2-pole thermal circuit breaker designed for equipment protection. It offers a rated current range of 0.05 to 20A AC and a DC voltage rating of 60VDC. The breaker operates with a thermal tripping mechanism and features a rocker actuation type, suitable for panel mounting.
Key electrical specifications include a rated AC voltage of 240VAC (IEC) and 277VAC (UL/CSA), with a conditional short circuit capacity of 2 kA at 240VAC. The device boasts a mechanical lifetime of 50,000 switching cycles and specific AC and DC lifetimes under load conditions. Environmental ratings include IP40 protection on the front side, an operating temperature range of -30°C to 60°C, and resistance to vibration and shock.
Applications for this circuit breaker include power tools, medical and laboratory equipment, industrial appliances, and commercial kitchen appliances. Its robust design and reliable performance make it suitable for various industrial and commercial uses requiring overcurrent protection.
The Schurter 4435.0185 is rated for 240 VAC (IEC), 277 VAC (UL/CSA), and 60 VDC.
The operating temperature range is -30 °C to 60 °C.
The current rating is 20 A, with an AC rated current range of 0.05 to 20 A.
It uses a rocker actuator.
It is a panel mount circuit breaker.
The front side has IP40 protection according to IEC 60529.
The mechanical lifetime is 50,000 switching cycles.