4435.013 The Schurter Inc. 4435.013 is a 2-pole thermal circuit breaker designed for panel mounting. It features a current rating of 4.5A and operates at 240VAC or 60VDC.
Mfr Part #:

4435.013

Mfr Name: Schurter Inc.
Schurter Inc.
The Schurter Inc. 4435.013 is a 2-pole thermal circuit breaker designed for panel mounting. It features a current rating of 4.5A and operates at 240VAC or 60VDC.
Stock on Request

4435.013 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Breaker Type
Current Rating (Amps)
Insulation Resistance
Mounting Type
Number of Poles
SVHC Present
Storage Temperature
Voltage Rating

4435.013 Description

Short technical summary and product information.

The Schurter Inc. 4435.013 is a 2-pole thermal circuit breaker with a rocker actuation type, suitable for panel mounting. It offers a rated current range of 0.05A to 20A AC, with a specific rating of 4.5A for this model, and a DC voltage rating of 60VDC, alongside an AC voltage rating of 240VAC (IEC) or 277VAC (UL/CSA).

 

This circuit breaker provides thermal tripping and thermal-magnetic protection, with a conditional short circuit capacity of 2 kA at 240 VAC. It is designed for a wide range of applications including power tools, medical and laboratory equipment, industrial appliances, and commercial kitchen appliances. The device has a mechanical lifetime of 50,000 switching cycles and operates within an ambient temperature range of -30°C to 60°C.

 

Key specifications include an IP40 degree of protection on the front side, dielectric strength greater than 2.5 kV at 50 Hz, and insulation resistance greater than 100 MΩ at 500 VDC. The unit weighs 32g (magnetic) or 56g. It is compliant with RoHS3 standards.

4435.013 Quick Information

Product Type: Circuit Breaker
Series: TA35
Canonical Name: Schurter Inc. TA35 Series Thermal Circuit Breaker
Subcategory: Thermal

4435.013 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

4435.013 Features

  • 2-pole thermal circuit breaker
  • 4.5A current rating
  • 240VAC / 60VDC voltage rating
  • Panel mount design
  • Thermal-magnetic tripping

4435.013 Applications

  • Suitable for power tools
  • Used in medical equipment
  • Ideal for industrial appliances
  • Applicable to construction equipment
  • Designed for cleaning equipment

4435.013 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the operating voltage of the Schurter 4435.013 circuit breaker?

The circuit breaker is rated for 240VAC (IEC) and 277VAC (UL/CSA) and 60VDC.

What is the operating temperature range?

-30°C to 60°C.

What is the current rating of this circuit breaker?

The specific model is rated for 4.5A, with the series supporting 0.05 to 20A.

What type of actuation does it have?

Rocker actuation.

What is the tripping type?

Thermal tripping, with thermal-magnetic also available.

What is the dielectric strength?

Greater than 2.5kV at 50Hz and greater than 4kV impulse.

What is the mounting type?

Panel mount.