| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4435.0029 is a 1-pole thermal circuit breaker designed for equipment protection. It utilizes a rocker actuation type and offers a panel mount configuration.
Key electrical specifications include a rated voltage of 240 VAC (IEC) or 277 VAC (UL/CSA) and 32 VDC. The current rating ranges from 0.05 A to 20 A, with a specific nominal rating of 2A. It has a conditional short circuit capacity of 2 kA at 240 VAC according to IEC 60934.
This circuit breaker operates within a temperature range of -30 °C to 60 °C and has a mechanical lifetime of 50,000 switching cycles. It meets IP40 degree of protection on the front side.
Applications for this series include power tools, medical and laboratory equipment, industrial appliances, and cleaning equipment.
AC ratings: 240 VAC (IEC) and 277 VAC (UL/CSA). DC rating: 32 VDC.
-30°C to 60°C.
2A (rated current range 0.05-20A).
Rocker actuation.
CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077.
50,000 switching cycles mechanical, 30,000 cycles AC, 50,000 cycles DC.
IP40 front side protection per IEC 60529.