| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Illumination Voltage (Nominal) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| SVHC Present | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
This Schurter Inc. 4430.3644 is a 2-pole thermal circuit breaker designed for equipment protection. It offers a rated current of 10A and operates at 240 VAC or 60 VDC.
The breaker features a thermal tripping mechanism and rocker actuation for ease of use. It is designed for panel mounting and has a mechanical lifetime of 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C.
Key technical specifications include a conditional short circuit capacity of 1 kA at 240 VAC and various short circuit capacities (Icn) depending on the current rating and voltage. It also has a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
240 VAC and 60 VDC.
10A.
2 poles.
-10°C to 55°C.
Panel mount.
CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077.
IP40 on the front side; IP54 with factory-mounted protection cover.