| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4430.3616 is a thermal circuit breaker featuring a 2-pole configuration and a rocker actuation type. It is designed for panel mounting and provides a rated current of 20A AC and a rated voltage of 240 VAC or 60 VDC.
This circuit breaker offers thermal overload protection with a positively trip-free release mechanism. Key technical specifications include a dielectric strength of 4 kVAC, insulation resistance greater than 100 MΩ at 500 VDC, and a mechanical lifetime of 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It meets various approval standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077.
The operating voltage is 240 VAC and 60 VDC.
The mounting type is panel mount.
The allowable operating temperature range is -10 °C to 55 °C.
It complies with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077.
The tripping type is thermal.
It has 2 poles.
The short circuit capacity Icn is 300 A at 240 VAC for rated current ≥ 3 A.