| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Illumination Voltage (Nominal) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4430.2056 is a thermal circuit breaker featuring a 2-pole configuration and rocker actuation. It is designed for panel mounting and provides thermal overload protection.
Key electrical specifications include a rated voltage of 240 VAC and 60 VDC, with a rated current range of 0.05 to 20 A. The breaker offers a conditional short circuit capacity of 1 kA at 240 VAC and various Icn ratings depending on current and voltage conditions. It has a mechanical lifetime of 50,000 switching cycles and an AC/DC lifetime of 50,000 switching cycles at 1x Ir.
Environmental and mechanical data include an operating temperature range of -10°C to 55°C, IP40 degree of protection (IP54 with a protection cover), and a weight between 30g and 50g. It meets vibration resistance standards up to 10 G @ 60 - 500 Hz and shock resistance of 30 G / 18 ms.
This circuit breaker is suitable for applications such as power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment. It holds approvals from VDE, UL, and CCC.
The breaker is rated for 240 VAC and 60 VDC.
-10°C to 55°C.
Thermal tripping.
2 poles.
Rocker actuation.
Panel mount.
Yes, green illumination at 10V nominal voltage.