| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4430.1849 is a 2-pole thermal circuit breaker designed for reliable overload protection. It features a 10A current rating and can handle up to 240VAC or 60VDC.
This circuit breaker offers a thermal tripping mechanism and a rocker actuation type. It is suitable for panel mounting and provides a degree of protection of IP40 on the front side. The device has a mechanical lifetime of 50,000 switching cycles and an operating temperature range of -10°C to 55°C.
Key technical specifications include a conditional short circuit capacity of 1 kA and a short circuit capacity of 300A. It also boasts a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment. It is approved by CSA, EN, GB, IEC, and UL standards.
The rated voltage for AC is 240 VAC and for DC is 60 VDC.
The current rating is 10A, with a rated current range of 0.05 - 20 A AC.
It uses rocker actuation.
The allowable operation temperature is -10°C to 55°C.
The RoHS status is RoHS3 Compliant.
The MSL is 1 Unlimited.
The REACH status is REACH Unaffected.