| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Illumination Voltage (Nominal) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4430.1826 is a thermal circuit breaker for equipment, offering 2-pole protection. It is rated for 240 VAC and 60 VDC, with a current rating of 12A.
This circuit breaker features a thermal tripping mechanism and a rocker actuation type. It is designed for panel mounting and has an IP40 degree of protection on the front side. The device has a mechanical lifetime of 50,000 switching cycles and an operating temperature range of -10 °C to 55 °C.
Key electrical specifications include a conditional short circuit capacity of 1 kA and a short circuit capacity (Icn) of up to 300A. It meets various approval standards, including CSA, EN, GB, IEC, and UL.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
240 VAC and 60 VDC.
12A.
2.
Thermal.
-10°C to 55°C.
IP40 (IP54 with cover).
50,000 switching cycles.