| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4430.1682 is a thermal circuit breaker designed for reliable overload protection in various applications. This 2-pole device offers a current rating of 15A and can handle up to 240VAC or 60VDC.
Key technical specifications include a conditional short circuit capacity of 1 kA at 240VAC and a tripping type that is thermal. The breaker is built for durability with a mechanical lifetime of 50,000 switching cycles and electrical lifetimes of 50,000 cycles at 1x Ir for both AC and DC.
Designed for ease of integration, the 4430.1682 features a panel mount configuration and a rocker actuation type. It operates within an ambient temperature range of -10°C to 55°C and offers a degree of protection of IP40 on the front side.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment. Its robust construction and thermal tripping mechanism ensure safety and operational continuity.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 15A.
It uses a rocker actuator.
The allowable operation temperature is -10°C to 55°C.
The front side offers IP40 protection, which can be upgraded to IP54 with a factory-mounted protection cover.
It is a 2-pole circuit breaker.