4430.1663 The Schurter Inc. 4430.1663 is a 2-pole thermal circuit breaker designed for panel mounting. It offers a 16A current rating and a 240VAC voltage rating.
Mfr Part #:

4430.1663

Mfr Name: Schurter Inc.
Schurter Inc.
The Schurter Inc. 4430.1663 is a 2-pole thermal circuit breaker designed for panel mounting. It offers a 16A current rating and a 240VAC voltage rating.
Stock on Request

4430.1663 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Breaker Type
Current Rating
Current Rating (Amps)
Illumination
Illumination Voltage (Nominal)
Industrial Grade
Insulation Resistance
Mounting Type
Number of Poles
Storage Temperature
Voltage Rating
Weight

4430.1663 Description

Short technical summary and product information.

The Schurter Inc. 4430.1663 is a thermal circuit breaker featuring a 2-pole configuration and rocker actuation. It is designed for panel mounting and has a rated current of 16A and a rated voltage of 240VAC.

 

This circuit breaker provides thermal overload protection with a positively trip-free release. Key electrical specifications include a rated voltage of 60VDC, a conditional short circuit capacity of 1 kA at 240VAC, and a short circuit capacity of 300A at 240VAC. The device operates within an allowable temperature range of -10°C to 55°C.

 

With a mechanical lifetime of 50,000 switching cycles, the 4430.1663 is built for durability. It meets various approval standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. The degree of protection is IP40 on the front side.

 

Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning.

4430.1663 Quick Information

Product Type: Circuit Breaker
Series: TA45
Canonical Name: Schurter Inc. TA45 Series Thermal Circuit Breaker, 16A, 240VAC, 2-Pole
Subcategory: Thermal

4430.1663 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

4430.1663 Features

  • 2-pole thermal circuit breaker
  • 16A current rating
  • 240VAC voltage rating
  • Rocker actuation
  • Panel mount design

4430.1663 Applications

  • Suitable for power tools
  • Used in industrial appliances
  • Applicable for power supplies
  • Designed for construction equipment
  • Used in cleaning equipment

4430.1663 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the operating voltage rating of the Schurter 4430.1663?

The circuit breaker is rated for 240 VAC and 60 VDC.

What is the current rating of the 4430.1663?

The rated current is 16A, with a full range of 0.05 to 20 A.

What is the operating temperature range?

-10°C to 55°C.

How many poles does the 4430.1663 have?

It has 2 poles.

What is the degree of protection?

IP40 (with optional cover achieving IP54).

What approvals does the 4430.1663 hold?

It is approved to CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077.

What is the mechanical lifetime?

50,000 switching cycles.