| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
This Schurter Inc. 4430.1624 is a thermal circuit breaker with a 2-pole configuration, suitable for various applications requiring reliable overload protection. It is designed for panel mounting and features a rocker actuation type.
The circuit breaker operates with a rated voltage of 240 VAC and 60 VDC, and has a current rating of 1.2A. It offers a conditional short circuit capacity of 1 kA at 240 VAC. The device is built to withstand 50,000 mechanical switching cycles and provides thermal overload protection.
Key technical specifications include a degree of protection of IP40 on the front side, dielectric strength of 4 kVAC, and insulation resistance greater than 100 MΩ at 500 VDC. The operating temperature range is from -10 °C to 55 °C.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It is designed for robust performance in demanding environments.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 1.2A.
This circuit breaker has 2 poles.
It uses rocker actuation.
The allowable operation temperature is -10 °C to 55 °C.