| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4430.1097 is a thermal circuit breaker designed for reliable overload protection. This 2-pole unit offers a rated current of 9A and operates at up to 240VAC or 60VDC.
Key technical specifications include a conditional short circuit capacity of 1 kA and a typical short circuit capacity of 300A. The breaker is designed for a mechanical lifetime of 50,000 switching cycles and has an operating temperature range of -10°C to 55°C.
Featuring Rocker actuation and a panel mount design, this circuit breaker is suitable for various industrial applications. It meets standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077, ensuring compliance and safety.
The degree of protection for the front side is IP40, which can be increased to IP54 with a factory-mounted protection cover. Insulation resistance is rated at >100 MΩ at 500 VDC, and dielectric strength is 4 kVAC.
240VAC and 60VDC.
-10 to 55°C.
Thermal.
50,000 switching cycles.
IP40 front side, IP54 with optional cover.
CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077.
Conditional short circuit capacity 1kA at 240VAC; Icn 300A at 240VAC for In ≥3A.