The Schurter 4430.099 is a 2-pole thermal circuit breaker featuring rocker actuation and a panel mount design. It provides thermal overload protection with a rated current of 6A and a rated voltage of 240VAC.
This circuit breaker is suitable for various industrial applications, including power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It operates within a temperature range of -10°C to 55°C and has a mechanical lifetime of 50,000 switching cycles.
Key specifications include a conditional short circuit capacity of 1 kA at 240VAC and a short circuit capacity of 300A at 240VAC. The degree of protection is IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. It also features a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC.
240 VAC and 60 VDC.
-10 °C to 55 °C.
Thermal.
2 poles.
4 kVAC.
50,000 switching cycles.
Panel mount.