4410.9002 The Schurter Inc. 4410.9002 is a 1-pole thermal circuit breaker designed for panel mounting. It features manual ON/OFF actuation and a 10A current rating.
Mfr Part #:

4410.9002

Mfr Name: Schurter Inc.
Schurter Inc.
The Schurter Inc. 4410.9002 is a 1-pole thermal circuit breaker designed for panel mounting. It features manual ON/OFF actuation and a 10A current rating.
Stock on Request

4410.9002 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Breaker Type
Current Rating (Amps)
Insulation Resistance
Mounting Type
Number of Poles
Operating Temperature
SVHC Present
Termination Style
Voltage Rating
Weight

4410.9002 Description

Short technical summary and product information.

The Schurter Inc. 4410.9002 is a thermal circuit breaker designed for equipment protection. It operates with a rated AC voltage of 240 VAC and a rated DC voltage of 28 VDC, with a current rating of 10A.

 

This single-pole breaker features manual ON/OFF actuation and a thermal tripping mechanism. It is designed for panel mounting and includes quick connect terminals (6.3 x 0.8 mm) or screw terminals. The device has a conditional short circuit capacity of 1 kA at 240 VAC.

 

Key electrical specifications include dielectric strength greater than 1.5 kV at 50 Hz and impulse withstand voltage greater than 2.5 kV. Insulation resistance is rated at over 100 MΩ at 500 VDC. The breaker offers typical endurance of 5000 switching cycles.

 

Environmental and mechanical specifications include an operating temperature range of -5 °C to 60 °C, vibration resistance according to IEC 60068-2-6, and shock resistance according to IEC 60068-2-27. It also features IK07 shock protection and is tested for salt spray resistance.

4410.9002 Quick Information

Product Type: Circuit Breaker
Series: T12-MSM
Canonical Name: Schurter Inc. T12-MSM Thermal Circuit Breaker
Subcategory: Thermal

4410.9002 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

4410.9002 Features

  • 10A thermal circuit breaker for equipment protection.
  • Rated for 240VAC and 28VDC operation.
  • Manual ON/OFF actuation with thermal tripping.
  • Panel mount design with quick connect/screw terminals.
  • Meets IEC 60934 and UL 1077 standards.

4410.9002 Applications

  • Suitable for power supplies.
  • Used in uninterruptible power supplies.
  • Applicable for power tools.
  • Designed for household appliances.

4410.9002 FAQs

6 frequently asked questions generated from this part’s specifications.
What is the rated current of the Schurter 4410.9002 circuit breaker?

The rated current is 10A.

What is the operating temperature range for this circuit breaker?

The operating temperature range is -5 °C to 60 °C.

What is the dielectric strength of the 4410.9002?

The dielectric strength is greater than 1.5 kV.

What mounting type does this circuit breaker use?

It uses panel mount with quick connect or screw terminals.

What is the insulation resistance of this device?

The insulation resistance is greater than 100 MΩ at 500 VDC.

What is the impulse withstand voltage rating?

The impulse withstand voltage is greater than 2.5 kV.