| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Breaker Type | |
| Current Rating (Amps) | |
| Halogen Free | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating | |
| Weight |
The Schurter 4400.0547 is a thermal circuit breaker designed for equipment protection. This 1-pole device features a threaded neck type and quick connect terminals (6.3 x 0.8 mm) for easy integration.
With a rated current of 3.3A and a voltage rating of 240VAC or 48VDC, it is suitable for various applications. The circuit breaker operates within an allowable temperature range of -5°C to 60°C and has a degree of protection of IP40 on the front side.
Key technical specifications include a conditional short circuit capacity of 2 kA at 240V AC and a typical endurance of 500 switching cycles at 2 x Ir. The actuation type is reset, and it supports panel mounting with an admissible torque on the fixing nut of up to 0.6 Nm.
This circuit breaker is designed for applications such as power tools, household equipment, power supplies and chargers, and industrial appliances. It complies with EU RoHS directive and IEC definition of halogen-free products.
The rated AC voltage for the Schurter 4400.0547 circuit breaker is 240 VAC.
The rated DC voltage for the Schurter 4400.0547 circuit breaker is 48 VDC.
The rated current range for the Schurter 4400.0547 circuit breaker is 0.05A to 16A.
The allowable operating temperature range for this circuit breaker is -5°C to 60°C.
Yes, the Schurter 4400.0547 circuit breaker is RoHS3 compliant.