4130-G411-K4M1-40A The E-T-A 4130-G411-K4M1-40A is a single-pole thermal circuit breaker designed for panel mounting. It offers a 40A current rating and supports 240VAC or 50VDC operation.
Mfr Part #:

4130-G411-K4M1-40A

Mfr Name: ETA
ETA
The E-T-A 4130-G411-K4M1-40A is a single-pole thermal circuit breaker designed for panel mounting. It offers a 40A current rating and supports 240VAC or 50VDC operation.
Stock on Request

4130-G411-K4M1-40A Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Ambient Temperature
Approval Agency
Breaker Type
Current Rating
Current Rating (Amps)
Illumination
Mounting Type
Number of Poles
Voltage Rating

4130-G411-K4M1-40A Description

Short technical summary and product information.

The E-T-A 4130-G411-K4M1-40A is a high-performance, single-pole thermal circuit breaker featuring a push-to-reset, trip-free snap-action mechanism compliant with EN 60934 (IEC 60934).

 

Designed for threadneck panel mounting, this breaker is suitable for applications requiring high fault current switching. It has a current rating of 40A and can operate at voltages up to 240VAC or 50VDC. The breaker offers an interrupting capacity of 800A at AC and up to 3500A at UL 1077 ratings.

 

Key technical data includes an operating temperature range of -30°C to +60°C and a degree of protection of IP40 for the operating area. The internal resistance at 40A is less than 0.01 Ω.

 

Typical applications for this circuit breaker include motors, transformers, solenoids, battery chargers, power supplies, appliances, and machinery. Its robust design and thermal protection make it a reliable choice for various industrial and commercial systems.

4130-G411-K4M1-40A Quick Information

Product Type: Circuit Breaker
Canonical Name: E-T-A 4130-G411-K4M1-40A Single Pole Thermal Circuit Breaker
Subcategory: Thermal

4130-G411-K4M1-40A Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

4130-G411-K4M1-40A Features

  • Single pole thermal circuit breaker.
  • 40A current rating.
  • 240VAC / 50VDC voltage rating.
  • Push-to-reset actuator.
  • Panel mount design.

4130-G411-K4M1-40A Applications

  • Suitable for motor protection.
  • Used in transformer circuits.
  • Applicable to power supplies.
  • Ideal for appliances.
  • Used in machinery.

4130-G411-K4M1-40A FAQs

7 frequently asked questions generated from this part’s specifications.
What is the current rating of the E-T-A 4130-G411-K4M1-40A circuit breaker?

The current rating is 40A.

What are the voltage ratings for the 4130-G411-K4M1-40A?

It is rated for 240 VAC and 50 VDC.

What type of circuit breaker is the 4130-G411-K4M1-40A?

It is a thermal circuit breaker.

How is the 4130-G411-K4M1-40A mounted?

It is designed for panel mounting.

What is the operating temperature range for this circuit breaker?

The operating temperature range is -30 to 60 °C.

What is the interrupting capacity of the 4130-G411-K4M1-40A?

The interrupting capacity is 800 A at AC and up to 3500 A at UL 1077 ratings.

What is the degree of protection for the operating area?

The degree of protection for the operating area is IP40.