| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating |
This E-T-A 412-K14-N2-20A is a single-pole, high-performance thermal circuit breaker. It utilizes a tease-free, trip-free, snap-action mechanism with manual push/pull on/off actuation. The breaker is panel mounted and features an indicator band on the push button to clearly show the tripped/off position.
Key electrical specifications include a voltage rating of 28V DC and a current rating of 20A. The interrupting capacity is rated at 6,000A. It operates within an ambient temperature range of -55°C to +75°C.
Designed for extra-low voltage wiring systems, typical applications include tracked vehicles, aircraft, and general-purpose equipment. The unit offers a degree of protection of IP40 in the operating area and IP00 at the terminals. It meets stringent environmental standards for vibration, shock, corrosion, and humidity.
The voltage rating is 28 V.
The current rating is 20 A.
The interrupting capacity is 6,000 A.
It uses panel mounting.
-55°C to +75°C.
It has an IP40 protection rating.