| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
This E-T-A 412-K14-LN2-35A is a high-performance, single-pole thermal circuit breaker. It is designed for panel mounting and features a manual push-pull ON/OFF actuation with an indicator band to clearly show the tripped/off position.
The circuit breaker operates with a nominal voltage rating of 115V AC or 28V DC and a current rating of 35A. It offers an interrupting capacity of 6,000A at both Icn and UL 1077 standards. The device is built with a tease-free, trip-free, snap-action mechanism.
Environmental specifications include an operating temperature range of -55°C to +75°C, IP40 protection for the operating area, and IP00 for the terminal area. It also meets stringent vibration, shock, corrosion, and humidity resistance standards, making it suitable for demanding applications.
Typical applications include extra-low voltage wiring systems on vehicles for land, sea, and air, as well as defense equipment and battery-powered machines. The 412-K14-LN2-35A is approved by CSA C22.2 No 235 and UL 1077.
The breaker is rated for 115V AC and 28V DC.
-55°C to +75°C.
Panel mount with push-pull plunger actuator.
6,000 A per UL 1077.
4,000 operations at 2x rated current.
IP40 on operating area, IP00 on terminals; vibration 10g (56-500Hz), shock 25g (11ms); humidity 240h at 95% RH; salt mist 96h at 5%.
35A.