412-K14-LN2-30A The E-T-A 412-K14-LN2-30A is a single-pole thermal circuit breaker designed for panel mounting. It features a 30A current rating and supports 115VAC or 28VDC operation.
Mfr Part #:

412-K14-LN2-30A

Mfr Name: ETA
ETA
The E-T-A 412-K14-LN2-30A is a single-pole thermal circuit breaker designed for panel mounting. It features a 30A current rating and supports 115VAC or 28VDC operation.
Stock on Request

412-K14-LN2-30A Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Ambient Temperature
Approval Agency
Breaker Type
Current Rating
Current Rating (Amps)
Illumination
Insulation Resistance
Mounting Type
Number of Poles
Voltage Rating

412-K14-LN2-30A Description

Short technical summary and product information.

The E-T-A 412-K14-LN2-30A is a high-performance, single-pole thermal circuit breaker. It utilizes a tease-free, trip-free, snap-action mechanism with manual push/pull on/off actuation. The breaker is designed for panel mounting and features an indicator band on the push button to clearly show the tripped/off position.

 

Key electrical specifications include a current rating of 30A and voltage ratings of 115V AC (400 Hz) and 28V DC. The interrupting capacity is rated at 6,000A for both Icn and UL 1077 standards. The operating temperature range is -55°C to +75°C.

 

This circuit breaker is suitable for extra-low voltage wiring systems in various applications, including tracked vehicles, aircraft, and general-purpose equipment. Its robust construction meets stringent environmental and mechanical testing standards, including vibration, shock, and humidity resistance.

 

Environmental compliance includes RoHS3 compliance, MSL 1, and REACH unaffected status. The degree of protection for the operating area is IP40, with the terminal area being IP00.

412-K14-LN2-30A Quick Information

Product Type: Circuit Breaker
Canonical Name: E-T-A 412-K14-LN2-30A Single Pole Thermal Circuit Breaker
Subcategory: Thermal Circuit Breaker

412-K14-LN2-30A Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

412-K14-LN2-30A Features

  • Single-pole thermal circuit breaker design.
  • Manual push-pull on/off actuation.
  • 30A current rating at 115VAC/28VDC.
  • Panel mountable for easy integration.
  • Rated for 6,000A interrupting capacity.

412-K14-LN2-30A Applications

  • Used in extra-low voltage systems.
  • Suitable for tracked vehicles.
  • Applicable for aircraft systems.
  • Ideal for battery-powered machines.
  • General purpose equipment applications.

412-K14-LN2-30A FAQs

6 frequently asked questions generated from this part’s specifications.
What is the current rating of the E-T-A 412-K14-LN2-30A circuit breaker?

The current rating is 30A.

What are the voltage ratings for the 412-K14-LN2-30A?

It supports 115V AC and 28V DC.

What type of circuit breaker is the 412-K14-LN2-30A?

It is a thermal circuit breaker.

How is the 412-K14-LN2-30A mounted?

It is designed for panel mounting.

What is the operating temperature range for this circuit breaker?

The operating temperature range is -55°C to +75°C.

What is the interrupting capacity of the 412-K14-LN2-30A?

The interrupting capacity is 6,000A.