| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Voltage Rating |
This E-T-A 412-K14-LN2-20A is a high-performance, single-pole thermal circuit breaker featuring a tease-free, trip-free, snap-action mechanism. It is manually actuated via a push/pull plunger and includes an indicator band to clearly show the tripped or off position. The breaker is designed for threadneck panel mounting.
Key electrical specifications include a current rating of 20A and voltage ratings of 115V AC and 28V DC. The interrupting capacity is rated at 6,000A for both Icn and UL 1077 standards. It operates within an ambient temperature range of -55°C to +75°C.
Environmental and mechanical robustness are ensured through compliance with various standards. It offers an operating area degree of protection of IP40 and terminal area of IP00. The breaker has undergone testing for vibration (10g), shock (25g), corrosion (96 hours salt mist), and humidity (240 hours at 95% RH).
Typical applications for this circuit breaker include extra-low voltage wiring systems on all types of vehicles (land, sea, air), defence equipment, and battery-powered machines. It is approved by CSA C22.2 No 235 and UL1077.
The 412-K14-LN2-20A has a current rating of 20A.
It supports 115VAC and 28VDC.
The operating temperature range is -55°C to +75°C.
It uses a push-pull plunger actuator.
It is a single-pole (1-pole) circuit breaker.
The interrupting capacity is 6,000A.
The breaker is panel mounted.