This E-T-A 412-K14-LN2-16A is a single-pole, thermal circuit breaker with a manual push-pull plunger actuator. It is designed for panel mounting and offers a current rating of 16A.
The breaker is suitable for extra low voltage wiring systems, including applications in tracked vehicles, aircraft, and general purpose equipment. It operates at AC voltages up to 115V and DC voltages up to 28V.
Key technical data includes an interrupting capacity of 6,000A at both Icn and UL 1077 standards. The operating temperature range is -55°C to +75°C. The unit provides an IP40 degree of protection for the operating area and IP00 for the terminal area.
Compliance is noted with UL1077 and CSA C22.2 No 235 approvals. The device has undergone vibration, shock, corrosion, and humidity testing according to various industry standards.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 16A.
It is rated for 115 V AC and 28 V DC.
It is a thermal circuit breaker.
It is a panel mount type.
The operating temperature range is -55 to +75 °C.
The interrupting capacity is 6,000 A.