3VA5190-1MH32-0AA0 The Siemens 3VA5190-1MH32-0AA0 is a 3-pole molded-case circuit breaker designed for starter protection. It offers a 90A operational current at 40°C and a 690V rated operating voltage.
Mfr Part #:

3VA5190-1MH32-0AA0

Mfr Name: Siemens
Siemens
The Siemens 3VA5190-1MH32-0AA0 is a 3-pole molded-case circuit breaker designed for starter protection. It offers a 90A operational current at 40°C and a 690V rated operating voltage.
Stock on Request
$ Price Range: $0.99

3VA5190-1MH32-0AA0 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Current Rating (Amps)
Illumination
Mounting Type
Number of Poles
Storage Temperature
Tape & Reel
Voltage
Voltage Rating

3VA5190-1MH32-0AA0 Description

Short technical summary and product information.

This Siemens 3VA5 molded-case circuit breaker, part number 3VA5190-1MH32-0AA0, is specifically designed for starter protection applications. It features a 3-pole configuration and a nominal operational current of 90A at 40°C, with ratings adjusted for higher ambient temperatures.

 

The breaker operates at a rated voltage of 690V AC and boasts a high breaking capacity, with a maximum short-circuit current (Icu) of 150kA at 240V and 70kA at 415V. It is equipped with a TM120M overcurrent release for protection.

 

Constructed for durability, the unit has a mechanical service life of typically 20,000 switching cycles. Its dimensions are 140mm in height, 76.2mm in width, and 76.5mm in depth. The breaker is designed for front connection using a nut keeper kit on both ends, accommodating conductor cross-sections from 12 x 1 mm up to 17 x 6.5 mm. It is suitable for HACR Type applications according to UL 489.

 

Additional technical data includes a maximum power loss of 18W and an active power loss per pole of 6W. The insulation voltage is rated at 800V.

3VA5190-1MH32-0AA0 Quick Information

Product Type: Molded-case circuit breaker
Canonical Name: Siemens 3VA5 Molded-case circuit breaker, 3-pole, 90A, 690V
Subcategory: Circuit Breakers

3VA5190-1MH32-0AA0 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

3VA5190-1MH32-0AA0 Estimated Pricing

Qty Low High
1+ $0.99 $0.99

Estimated market price range - modelled values for guidance only, not live distributor offers.

3VA5190-1MH32-0AA0 Features

  • 3-pole molded-case circuit breaker.
  • 90A operational current at 40°C.
  • 690V AC rated operating voltage.
  • High short-circuit breaking capacity.
  • UL 489 HACR Type listed.

3VA5190-1MH32-0AA0 Applications

  • Starter protection applications.
  • HACR Type circuits.
  • Industrial control panels.
  • Power distribution systems.

3VA5190-1MH32-0AA0 FAQs

5 frequently asked questions generated from this part’s specifications.
What is the operating voltage for this circuit breaker?

The rated operating voltage for this circuit breaker at AC is 690 V.

What is the maximum operational current at 40°C?

The operational current at 40°C is 90 A.

What is the short-circuit breaking capacity at 240V?

The maximum short-circuit current breaking capacity (Icu) at 240 V is 150 kA.

What is the mechanical service life of this breaker?

The typical mechanical service life is 20,000 switching cycles.

What are the dimensions of this circuit breaker?

The dimensions are 140 mm in height, 76.2 mm in width, and 76.5 mm in depth.