3VA5140-4ED32-0AA0 The Siemens 3VA5140-4ED32-0AA0 is a 3-pole molded-case circuit breaker designed for system protection. It offers a 40A operational current at 40°C and a rated operational voltage of 690V AC.
Mfr Part #:

3VA5140-4ED32-0AA0

Mfr Name: Siemens
Siemens
The Siemens 3VA5140-4ED32-0AA0 is a 3-pole molded-case circuit breaker designed for system protection. It offers a 40A operational current at 40°C and a rated operational voltage of 690V AC.
Stock on Request
$ Price Range: $0.99

3VA5140-4ED32-0AA0 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Current Rating (Amps)
Depth
Height
Illumination
Mounting Type
Number of Poles
Voltage Rating
Width

3VA5140-4ED32-0AA0 Description

Short technical summary and product information.

The Siemens 3VA5140-4ED32-0AA0 is a molded-case circuit breaker from the SENTRON series, designed for system protection applications. This 3-pole breaker features a TM210 overcurrent release with LI protection function.

 

It has a rated insulation voltage (Ui) of 800V and a maximum rated operational voltage (Ue) of 500V DC, with a rated operational voltage of 690V AC. The breaker can handle an operational current of 40A at 40°C, with derated values at higher temperatures. Its breaking capacity according to IEC 60947 is 55kA at 240V and 36kA at 415V. Under UL 489 standards, it offers a breaking capacity of 25kA at 480V.

 

With a mechanical service life of typically 20,000 switching cycles, the 3VA5140-4ED32-0AA0 is built for durability. It has a maximum power loss of 11.2W. The dimensions are 140mm in height, 76.2mm in width, and 76.5mm in depth. Mounting is designed for DIN rail installation.

 

This circuit breaker is HACR Type compliant according to UL 489. It does not feature communication or other measurement functions. The environmental compliance includes RoHS3, MSL 1, and REACH Unaffected status, though these are treated with low confidence due to lack of verification.

3VA5140-4ED32-0AA0 Quick Information

Product Type: Molded-case circuit breaker
Series: 3VA5
Canonical Name: Siemens 3VA5140-4ED32-0AA0 Molded-case circuit breaker
Subcategory: Molded-case circuit breaker

3VA5140-4ED32-0AA0 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

3VA5140-4ED32-0AA0 Estimated Pricing

Qty Low High
1+ $0.99 $0.99

Estimated market price range - modelled values for guidance only, not live distributor offers.

3VA5140-4ED32-0AA0 Features

  • 3-pole molded-case circuit breaker.
  • 40A operational current at 40°C.
  • 690V AC rated operational voltage.
  • DIN rail mounting type.
  • TM210 overcurrent release with LI protection.

3VA5140-4ED32-0AA0 Applications

  • Suitable for HACR Type applications.
  • Used for system protection.
  • Industrial control panel applications.
  • Power distribution circuits.

3VA5140-4ED32-0AA0 FAQs

5 frequently asked questions generated from this part’s specifications.
What is a molded case circuit breaker used for?

A molded case circuit breaker (MCCB) is an electrical safety device designed to protect circuits and equipment from overload and short circuit damage. It automatically interrupts the flow of electricity when it detects abnormal current conditions, preventing potential fires and equipment failure.

What is the operational current rating of the Siemens 3VA5140-4ED32-0AA0 at 40°C?

The operational current rating of the Siemens 3VA5140-4ED32-0AA0 at 40°C is 40A.

What is the rated operational voltage for the 3VA5140-4ED32-0AA0 circuit breaker?

The rated operational voltage for the 3VA5140-4ED32-0AA0 circuit breaker is 690V AC.

How many poles does the 3VA5140-4ED32-0AA0 circuit breaker have?

The 3VA5140-4ED32-0AA0 circuit breaker has 3 poles.

What is the breaking capacity of the 3VA5140-4ED32-0AA0 at 480V according to UL 489?

The breaking capacity of the 3VA5140-4ED32-0AA0 at 480V according to UL 489 is 25 kA.

3VA5140-4ED32-0AA0 Alternate Parts

Same form/fit/function or matching attribute configuration across different manufacturers.
View All Alternate Parts
3VA5140-5EC32-0AA0
3VA5140-5EC32-0AA0
Siemens
The Siemens 3VA5140-5EC32-0AA0 is a 3-pole molded-case circuit breaker with a 40A current rating and a 690V AC operating voltage. It offers a breaking capacity of 35kA at 480V.
View Part
3VA5140-5EF32-0AA0
3VA5140-5EF32-0AA0
Siemens
The Siemens 3VA5140-5EF32-0AA0 is a 3-pole molded-case circuit breaker rated for 40A and 690V. It features a TM240 trip unit with adjustable overload and short-circuit protection.
View Part
3VA5140-6EC32-0AA0
3VA5140-6EC32-0AA0
Siemens
The Siemens 3VA5140-6EC32-0AA0 is a 3-pole molded-case circuit breaker rated for 40A and 690V. It features a breaking capacity of 65kA at 480V.
View Part
3VA5140-6ED32-1AA0
3VA5140-6ED32-1AA0
Siemens
The Siemens 3VA5140-6ED32-1AA0 is a 3-pole molded-case circuit breaker designed for system protection. It offers a 40A operational current and a breaking capacity of 65kA at 480V.
View Part
Home
Account

Categories