3VA5112-4ED22-0AA0 The Siemens SENTRON 3VA5112-4ED22-0AA0 is a 2-pole molded-case circuit breaker with a 125A current rating and a breaking capacity of 25kA at 480V.
Mfr Part #:

3VA5112-4ED22-0AA0

Mfr Name: Siemens
Siemens
The Siemens SENTRON 3VA5112-4ED22-0AA0 is a 2-pole molded-case circuit breaker with a 125A current rating and a breaking capacity of 25kA at 480V.
Stock on Request
$ Price Range: $0.99

3VA5112-4ED22-0AA0 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Connection Type
Current Rating
Current Rating (Amps)
Depth
Height
Illumination
Mounting Type
Number of Poles
Voltage Rating
Width

3VA5112-4ED22-0AA0 Description

Short technical summary and product information.

This Siemens SENTRON 3VA5112-4ED22-0AA0 is a 2-pole molded-case circuit breaker designed for system protection. It features a rated insulation voltage of 600V and an operating voltage of 415V AC. The breaker has a nominal current rating of 125A at 40°C, with derated values at higher temperatures.

 

With a breaking capacity of 25kA at 480V according to UL 489, and 36kA at 415V according to IEC 60947, this circuit breaker offers robust protection. It utilizes the TM210 overcurrent release with LI protection function. The mechanical service life is typically 20,000 switching cycles.

 

The unit is designed for DIN rail mounting and features front connections for the main current circuit. Its dimensions are 140mm in height, 50.8mm in width, and 76.5mm in depth. The breaker is also listed as HACR Type.

3VA5112-4ED22-0AA0 Quick Information

Product Type: Molded-case circuit breaker
Series: SENTRON
Canonical Name: Siemens SENTRON 3VA5 Molded-case circuit breaker
Subcategory: Circuit Breakers

3VA5112-4ED22-0AA0 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

3VA5112-4ED22-0AA0 Estimated Pricing

Qty Low High
1+ $0.99 $0.99

Estimated market price range - modelled values for guidance only, not live distributor offers.

3VA5112-4ED22-0AA0 Features

  • 2-pole molded-case circuit breaker
  • 125A current rating at 40°C
  • 25kA breaking capacity at 480V (UL 489)
  • TM210 overcurrent release with LI protection
  • DIN rail mounting with front connections

3VA5112-4ED22-0AA0 Applications

  • Suitable for system protection applications
  • Designed for HVAC and refrigeration circuits
  • Industrial control panel applications
  • Power distribution systems

3VA5112-4ED22-0AA0 FAQs

5 frequently asked questions generated from this part’s specifications.
What is the current rating of the Siemens 3VA5112-4ED22-0AA0 circuit breaker?

The current rating is 125A at 40°C.

What is the breaking capacity of the 3VA5112-4ED22-0AA0 at 480V?

The breaking capacity according to UL 489 is 25kA at 480V.

How many poles does the Siemens 3VA5112-4ED22-0AA0 have?

This circuit breaker has 2 poles.

What type of overcurrent release does this breaker use?

It uses the TM210 overcurrent release with LI protection function.

What is the mounting type for this circuit breaker?

The mounting type is DIN Rail.

Home