3VA5112-1MH32-0AA0 The Siemens 3VA5112-1MH32-0AA0 is a 3-pole molded-case circuit breaker designed for starter protection. It offers a 125A operational current and a 690V AC rated operating voltage.
Mfr Part #:

3VA5112-1MH32-0AA0

Mfr Name: Siemens
Siemens
The Siemens 3VA5112-1MH32-0AA0 is a 3-pole molded-case circuit breaker designed for starter protection. It offers a 125A operational current and a 690V AC rated operating voltage.
Stock on Request
$ Price Range: $0.99

3VA5112-1MH32-0AA0 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Connection Type
Current Rating
Current Rating (Amps)
Depth
Height
Illumination
Mounting Type
Number of Poles
Storage Temperature
Tape & Reel
Voltage
Voltage Rating
Width

3VA5112-1MH32-0AA0 Description

Short technical summary and product information.

The Siemens SENTRON 3VA5112-1MH32-0AA0 is a molded-case circuit breaker designed for starter protection applications. This 3-pole unit features an operational current of 125A at 40°C, with derated values at higher temperatures.

 

With a rated insulation voltage of 800V and an operating voltage of 690V AC, this circuit breaker provides robust protection. It boasts a high breaking capacity, with a maximum short-circuit current (Icu) of 150kA at 240V and 70kA at 415V. The mechanical service life is typically 20,000 switching cycles.

 

The device has a compact mechanical design with dimensions of 140mm height, 76.2mm width, and 76.5mm depth. It is designed for front connection using a nut keeper kit on both ends. The breaker is HACR Type compliant according to UL 489.

 

This circuit breaker is suitable for various industrial and commercial applications requiring reliable overcurrent protection. Its robust construction and high performance specifications ensure safe and efficient operation.

3VA5112-1MH32-0AA0 Quick Information

Product Type: Molded-case circuit breaker
Series: SENTRON
Canonical Name: Siemens SENTRON 3VA5 Molded-case circuit breaker, Starter protection, 3-pole, 125A, 690V
Subcategory: Molded Case Circuit Breaker

3VA5112-1MH32-0AA0 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

3VA5112-1MH32-0AA0 Estimated Pricing

Qty Low High
1+ $0.99 $0.99

Estimated market price range - modelled values for guidance only, not live distributor offers.

3VA5112-1MH32-0AA0 Features

  • 3-pole molded-case circuit breaker
  • 125A operational current at 40°C
  • 690V AC rated operating voltage
  • 150kA breaking capacity at 240V
  • Starter protection, HACR Type compliant

3VA5112-1MH32-0AA0 Applications

  • Industrial motor starter protection
  • HVAC and refrigeration circuits
  • Power distribution systems
  • Control panel applications

3VA5112-1MH32-0AA0 FAQs

6 frequently asked questions generated from this part’s specifications.
What is the operational current rating of the Siemens 3VA5112-1MH32-0AA0 circuit breaker?

The operational current is 125A at 40°C, derating to 109A at 70°C.

What is the maximum AC operating voltage for this circuit breaker?

The rated operating voltage at AC is 690 V.

What is the breaking capacity of the 3VA5112-1MH32-0AA0 at 415V?

The maximum short-circuit current breaking capacity (Icu) at 415V is 70 kA, and the operating short-circuit current breaking capacity (Ics) is also 70 kA.

How many poles does the Siemens 3VA5112-1MH32-0AA0 have?

This circuit breaker has 3 poles.

What is the mechanical service life of this circuit breaker?

The typical mechanical service life is 20,000 switching cycles.

Is this circuit breaker HACR Type compliant?

Yes, it is designed as a load switch according to UL 489 for Heating, Air Conditioning, and Refrigeration (HACR Type) applications.