3VA5102-1MH31-0AA0 The Siemens 3VA5102-1MH31-0AA0 is a 3-pole molded-case circuit breaker with a 2A current rating and a maximum operational voltage of 690V. It offers a breaking capacity of up to 150kA at 240V.
Mfr Part #:

3VA5102-1MH31-0AA0

Mfr Name: Siemens
Siemens
The Siemens 3VA5102-1MH31-0AA0 is a 3-pole molded-case circuit breaker with a 2A current rating and a maximum operational voltage of 690V. It offers a breaking capacity of up to 150kA at 240V.
Stock on Request
$ Price Range: $0.99

3VA5102-1MH31-0AA0 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Current Rating (Amps)
Depth
Height
Illumination
Mounting Type
Number of Poles
Storage Temperature
Tape & Reel
Voltage Rating
Width

3VA5102-1MH31-0AA0 Description

Short technical summary and product information.

This Siemens 3VA5102-1MH31-0AA0 is a molded-case circuit breaker designed for starter protection applications. It features a 3-pole configuration and a permanent rated current of 2A, maintaining this rating across operating temperatures from 40°C to 70°C.

 

The circuit breaker operates at a maximum rated operational voltage of 690V AC and has an insulation voltage of 800V. It provides robust short-circuit protection with a maximum breaking capacity (Icu) of 150kA at 240V and 70kA at 415V. The operating short-circuit breaking capacity (Ics) is also 150kA at 240V and 70kA at 415V. The adjustable response current (Ii) ranges from 10A to 24A.

 

With a mechanical service life of typically 15,000 switching cycles and electrical endurance ratings of up to 8,000 cycles at 380/415V, this breaker is built for durability. It has a compact mechanical design with dimensions of 140mm height, 76.2mm width, and 76.5mm depth. The mounting type is DIN Rail, and it features a lever actuator.

 

Environmental specifications include an operating ambient temperature range of -25°C to 70°C and a protection class of IP40 on the front. The breaker is compliant with various approval agencies including UL489 and is HACR Type certified.

3VA5102-1MH31-0AA0 Quick Information

Product Type: Molded-case circuit breaker
Canonical Name: Siemens 3VA5 Molded-case circuit breaker, 3-pole, 2A, 690V
Subcategory: Molded-case circuit breaker

3VA5102-1MH31-0AA0 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

3VA5102-1MH31-0AA0 Estimated Pricing

Qty Low High
1+ $0.99 $0.99

Estimated market price range - modelled values for guidance only, not live distributor offers.

3VA5102-1MH31-0AA0 Features

  • 3-pole molded-case circuit breaker
  • 2A continuous current rating
  • 690V maximum operational voltage
  • 150kA breaking capacity at 240V
  • DIN rail mounting type

3VA5102-1MH31-0AA0 Applications

  • Ideal for starter protection applications
  • Suitable for HACR Type installations
  • Used in systems requiring UL489 compliance
  • General purpose circuit protection needs

3VA5102-1MH31-0AA0 FAQs

5 frequently asked questions generated from this part’s specifications.
What is the current rating of the Siemens 3VA5102-1MH31-0AA0 circuit breaker?

The permanent rated current (Iu) is 2A, and the operational current is 2A at temperatures up to 70°C.

What is the maximum operational voltage for this circuit breaker?

The maximum rated operational voltage (Ue) with AC 50/60Hz is 690 V.

What is the short-circuit breaking capacity of the 3VA5102-1MH31-0AA0?

The maximum short-circuit breaking capacity (Icu) is 150kA at 240V, 70kA at 415V, and 10kA at 690V.

What is the operating temperature range for this circuit breaker?

The circuit breaker can operate in ambient temperatures from -25°C to 70°C.

Is this circuit breaker RoHS compliant?

The RoHS status is listed as RoHS3 Compliant.

Home