| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| SVHC Present | |
| Voltage Rating |
The E-T-A 3120-N521-P7T1-W01D-20A is a thermal circuit breaker that combines overcurrent protection with the function of an ON/OFF switch. This 2-pole device features a thermal-bimetal trip element and is suitable for overload protection of motors, pumps, transformers, and cables.
Key electrical specifications include a voltage rating of up to 415V AC and a current rating of 20A. The breaker is designed for panel mounting and features a rocker actuator. It is approved by CSA, GB, IEC, and UL standards.
This circuit breaker is designed for reliable operation and easy reset after tripping. Its positively trip-free mechanism ensures reliable disconnection even when the actuator is blocked. The device is also suitable for use in medical equipment according to IEC/EN 60601 standards, ensuring maximum equipment availability through overload protection matched to loads and quick resettability.
Typical applications include medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, office machines, audio equipment, and machine tools.
The voltage rating is 415V AC and 50V DC.
The current rating is 20A.
This circuit breaker has 2 poles.
It is a thermal circuit breaker.
The mounting type is Panel Mount.
The RoHS status is RoHS3 Compliant.
The MSL is 1 Unlimited.