| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 3120-N32G-P7T1-D01X-1A is a thermal circuit breaker that combines overcurrent protection with the function of an ON/OFF switch. It utilizes a thermal-bimetal trip element and is suitable for overload protection of motors, pumps, transformers, and cables. After tripping, it can be easily and quickly reset.
This 2-pole circuit breaker has a current rating of 1A and a voltage rating of 415V. It features a pushbutton actuator and is designed for panel mounting. The 3120-N series is also available with thermal-magnetic trip options and can be expanded with various add-on modules for enhanced functionality.
Typical applications for this type of circuit breaker include medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, office machines, and audio equipment. Its design ensures reliable disconnection and maximum equipment availability through overload protection matched to the loads and quick resettability.
The current rating is 1A.
The voltage rating is 415V.
This circuit breaker has 2 poles.
It is a thermal circuit breaker.
It uses a pushbutton actuator.
The mounting type is Panel Mount.
Approval agencies include CSA C22.2 No 235, GB 17701, IEC 60934, and UL1077.