| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| Rated Voltage | |
| Voltage Rating |
The E-T-A 3120-N32G-P7T1-D01X-16A is a thermal circuit breaker designed for overcurrent protection and switch functionality. It combines these two functions into a single component, utilizing a thermal bimetal trip element.
This 2-pole circuit breaker has a current rating of 16A and a voltage rating of 415V. It is designed for panel mounting and features pushbutton actuation. The device is suitable for overload protection of motors, pumps, transformers, and cables, offering reliable disconnection and quick reset capabilities.
Key specifications include a rated voltage of AC 240V and DC 50V, with AC 415V available upon request. The current rating range is typically 0.1 to 20A. The datasheet indicates a typical life of 30,000 cycles at 1x IN for inductive loads.
Typical applications for this type of circuit breaker include medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, office machines, audio equipment, and machine tools.
The voltage rating is 415V AC. Additionally, the rated voltage is AC 240 V and DC 50 V (AC 415 V upon request).
The current rating is 16A.
It has 2 poles.
The breaker type is thermal.
Panel mount.
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077.
30,000 cycles at 1 x IN, inductive.