| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 3120-N324-P7T1-W01L-20A is a thermal circuit breaker that combines overcurrent protection with the function of an ON/OFF switch. It utilizes a bimetal trip element and is suitable for overload protection of motors, pumps, transformers, and cables. The device can be easily and quickly reset after tripping.
This 2-pole circuit breaker has a current rating of 20A and supports voltage ratings of 240 VAC and 50 VDC, with 415 VAC available upon request. It is designed for panel mounting and features a rocker actuator. The breaker is approved by CSA, GB, IEC, and UL standards.
Typical applications for this series include medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, office machines, audio equipment, and machine tools. Its design ensures reliable disconnection and maximum equipment availability through overload protection matched to loads and quick resettability.
The current rating is 20A.
It is rated for 240 VAC and 50 VDC, with 415 VAC available upon request.
This circuit breaker has 2 poles.
It is a thermal circuit breaker.
The mounting type is Panel Mount.
It is approved by CSA C22.2 No 235, GB 17701, IEC 60934, and UL1077.
Yes, it is RoHS3 Compliant.