| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating |
This E-T-A 3120-N series thermal circuit breaker, part number 3120-N324-H7T1-W01D-X3120-U0203M-16A, offers combined overcurrent protection and ON/OFF switch functionality. It is a 2-pole device with a rocker actuator and a panel mount design.
Key electrical specifications include a current rating of 16A and a voltage rating of 415V AC. The internal resistance per pole is less than 0.02 Ohm. The breaker is approved by CSA C22.2 No 235, GB 17701, IEC 60934, and UL1077.
This thermal circuit breaker utilizes a bimetal trip element and is suitable for overload protection of motors, pumps, transformers, and cables. It is designed for easy and quick resetting after tripping. The device is also suitable for use in medical equipment according to IEC/EN 60601.
Typical applications include medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, office machines, audio equipment, and machine tools.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 16A.
The voltage rating is 415V AC.
It has 2 poles.
It is a Thermal circuit breaker.
The mounting type is Panel Mount.
The RoHS status is RoHS3 Compliant.