The E-T-A 3120-N321-P7T1-W19DG4-15A is a two-pole thermal circuit breaker that combines overcurrent protection with the function of an ON/OFF switch. It features a bimetal trip element and is suitable for overload protection of motors, pumps, transformers, and cables. The breaker can be reliably reset after tripping.
Key electrical specifications include a current rating of 15A and a voltage rating of 415V. The datasheet indicates rated voltages of AC 240V and DC 50V, with a current rating range from 0.1 to 20A. Typical life is rated for 30,000 cycles under various conditions.
This circuit breaker is designed for panel mounting and features a rocker actuator. It also includes green illumination for a 230V nominal voltage. Approval agencies include CSA, GB, IEC, and UL.
Typical applications for this type of thermal circuit breaker include medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, office machines, audio equipment, and machine tools.
The circuit breaker is rated for 250VAC and 50VDC.
15A.
2 poles.
CSA C22.2 No 235, GB 17701, IEC 60934, UL1077.
Rocker actuator with green illumination at 230V nominal.
Panel mount.