The E-T-A 3120-F304-N7Q1-W12DY6-20A is a thermal circuit breaker designed for overload protection of motors, pumps, transformers, and cables. It functions as an ON/OFF switch with integral overcurrent protection, utilizing a bimetal trip element.
This two-pole breaker has a current rating of 20A and supports a voltage rating of 250VAC and 50VDC. It is designed for panel mounting and features rocker actuation. The breaker offers reliable switching behavior with a positively trip-free mechanism.
Typical applications include medical and laboratory equipment, apparatus and machine construction, professional tools, household and garden appliances, office machines, and audio equipment. The operating temperature range is -30 to 60 °C, and it has a typical life of 50,000 operations at 1 x IN under inductive load conditions for 2-pole configurations at AC 240V.
Compliance includes CSA C22.2 No 235, GB 17701, IEC 60934, and UL1077. The breaker has an interrupting capacity of 5000A at AC 250V and 1000A at DC 50V.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 20A.
The voltage rating is 250VAC and 50VDC.
It is designed for panel mounting.
It features rocker actuation.
The ambient temperature range is -30 to 60 °C.
The typical life is 50,000 operations at 1 x IN under inductive load conditions for 2-pole configurations at AC 240V.