The Schurter Inc. 3-128-215 is a 2-pole TA36 Rocker series circuit breaker designed for thermal and thermal-magnetic operation. It features a rocker actuation type and a panel mount configuration.
This circuit breaker has a rated AC voltage of 240 VAC (IEC) and 277 VAC (UL/CSA), with a DC voltage rating of 32 VDC for 1-pole and 60 VDC for 2-pole configurations. The rated current range is 0.05 to 20 A AC, with a magnetic limit up to 16 A. It offers a conditional short circuit capacity of 2 kA at 240 VAC according to IEC 60934.
Environmental specifications include a degree of protection of IP40 on the front side. The operating temperature range is -30 °C to 60 °C, and the storage temperature range is -40 °C to 60 °C. Mechanical lifetime is rated at 50,000 switching cycles.
Applications for this circuit breaker include power tools, medical and laboratory equipment, industrial appliances, equipment for construction, cleaning equipment, commercial and household kitchen appliances, industrial power, and industrial lighting arrays.
AC ratings: 240VAC (IEC) and 277VAC (UL/CSA). DC ratings: 32VDC for 1-pole, 60VDC for 2-pole.
Panel mount.
-30 °C to 60 °C.
20A AC, with thermal trip range of 0.05 to 20A.
50,000 switching cycles.
CCC, CE, cURus, and VDE.