The Phoenix Contact 2305460 is a pre-assembled shielded D-Sub cable from the CABLE-D...SUB family. It features DB15 receptacles with female sockets on both ends, a gray jacket, and a length of 3 meters (9.84 feet).
The cable is shielded with a tinned copper braid providing approximately 85% coverage, making it suitable for use in environments prone to electromagnetic interference. Each conductor has a cross-section of 0.25 mm² (24 AWG) and a maximum conductor resistance of 0.09 Ω/m.
Each signal path can carry up to 2 A, and the cable is rated for a maximum permissible operating voltage of 25 V AC or 60 V DC. The assembly is tested for short circuit, polarity reversal, and open circuit to ensure proper operation. The connectors are designed for more than 200 insertion/withdrawal cycles and operate within an ambient temperature range of -20°C to 50°C.
This cable is ideal for use as a control and signal cable in industrial communication applications, particularly when connecting to VARIOFACE interface modules.
The ambient operating temperature range is -20°C to 50°C.
The maximum permissible operating voltage is 25 V AC or 60 V DC.
The cable is listed as RoHS3 Compliant, but this has not been independently verified.
It has a tinned copper braided shield with approximately 85% coverage.
Each signal path can carry up to 2 A.
The connectors are rated for more than 200 insertion/withdrawal cycles.
The conductor cross-section is 0.25 mm², equivalent to 24 AWG.