2056-35-B2LF Bourns 2056-35-B2LF is a 3-electrode gas discharge tube with 350V DC sparkover voltage and 5kA impulse discharge current. It comes in a through-hole package with radial leads.
Mfr Part #:

2056-35-B2LF

Available from 2 distributors
Mfr Name: Bourns
Bourns
Bourns 2056-35-B2LF is a 3-electrode gas discharge tube with 350V DC sparkover voltage and 5kA impulse discharge current. It comes in a through-hole package with radial leads.
✓ Total Stock: 96 pcs

2056-35-B2LF Available from 2 distributors

✓ Authorised
✓ Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
48 pcs
48 pcs On Request 1 On Request On Request On Request On Request On Request
Non-Authorised Inventory information
48 pcs
48 pcs On Request 1 On Request On Request On Request On Request On Request

2056-35-B2LF Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
AEC Qualified
Automotive Grade
Capacitance
Diameter
Fail Short
Impulse Discharge Current (8
Industrial Grade
Insulation Resistance
Lead Style
Length
Medical Grade
Military Grade
Mounting Type
Number of Poles
Operating Temperature Range
Package / Case
Prop 65
Storage Temperature
Tape & Reel
Tolerance
Voltage

2056-35-B2LF Description

Short technical summary and product information.

The Bourns 2056-35-B2LF is a light-duty 3-electrode gas discharge tube (GDT) designed for overvoltage protection. It features a DC sparkover voltage of 350V with ±20% tolerance, and can handle impulse discharge currents up to 5kA (8/20μs waveform, 10 operations). The device has low capacitance (<2pF) and high insulation resistance (>1GΩ), making it suitable for high-speed signal lines. It operates over a temperature range of -30°C to +85°C. The component is housed in an axial cylinder package with three radial leads for through-hole mounting. It is RoHS compliant and UL recognized.

2056-35-B2LF Quick Information

Product Type: Gas Discharge Tube (GDT)
Series: 2056
Canonical Name: Bourns 2056-35-B2LF Gas Discharge Tube, 350V DC Sparkover, 5kA Impulse, 3-Pole, Through Hole
Subcategory: Light Duty 3-Electrode

2056-35-B2LF Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

2056-35-B2LF Features

  • 350V DC sparkover voltage with ±20% tolerance.
  • 5kA impulse discharge current capability.
  • Low capacitance of less than 2pF.
  • Through-hole mounting with radial leads.
  • RoHS compliant and UL recognized.

2056-35-B2LF Applications

  • Used in telecom line protection circuits.
  • Ideal for data line surge protection.
  • Suitable for power supply overvoltage protection.
  • Applied in industrial control systems.

2056-35-B2LF FAQs

7 frequently asked questions generated from this part’s specifications.
What is the DC sparkover voltage?

350V ±20%.

What is the maximum impulse discharge current?

5kA (8/20μs, 10 operations).

What is the operating temperature range?

-30°C to +85°C.

Is this component RoHS compliant?

Yes, RoHS3 compliant per Directive 2015/863.

What is the package type?

Axial cylinder, 3 lead (radial bend), through hole.

What is the insulation resistance?

>1 GΩ.

What is the capacitance?

<2 pF.

Home