Have a small number of parts or want to add parts manually? Request Quote manually

Search across all market segments

2031-42T-SM-RPLF Surface mount 2-pole gas discharge tube (GDT) with 360V minimum DC sparkover and 1kA impulse discharge current rating. Designed for overvoltage protection in telecom and industrial applications.
Mfr Part #:

2031-42T-SM-RPLF

Available from 1 distributors
Mfr Name: Bourns
Bourns
Surface mount 2-pole gas discharge tube (GDT) with 360V minimum DC sparkover and 1kA impulse discharge current rating. Designed for overvoltage protection in telecom and industrial applications.
Total Stock: 265 pcs

2031-42T-SM-RPLF Available from 1 distributor

Authorised
Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
265 pcs
265 pcs On Request 1 On Request On Request On Request On Request On Request

2031-42T-SM-RPLF Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Arc Voltage
Automotive Grade
Capacitance
DC Holdover Voltage
DC Sparkover Voltage
Fail Short
Glow Voltage
Glow-Arc Transition Current
Impulse Discharge Current
Impulse Discharge Current (8
Industrial Grade
Insulation Resistance
Maximum Impulse Sparkover Voltage
Medical Grade
Military Grade
Minimum DC Sparkover Voltage
Mounting Type
Number of Poles
Operating and Storage Temperature Range
Service Life (10/1000 µs, 1 kV, 100 A)
Service Life (10/700 µs, 6 kV, 150 A)
Service Life (2/10 µs, 5 kV, 500 A)
Service Life (600 V rms, 1 A, 0.2 s)
Service Life (8/20 µs 250 A, 1.2/50 µs 500 V)
Service Life (8/20 µs, 1 kA)
Storage Temperature
Voltage

2031-42T-SM-RPLF Description

Short technical summary and product information.

The Bourns 2031-42T-SM-RPLF is a miniature 2-pole gas discharge tube (GDT) in a surface mount package. It provides reliable overvoltage protection with a typical DC sparkover of 420V and a minimum of 360V throughout service life. The impulse sparkover is 850V max at 5kV 1.2/50µs waveform. With an impulse discharge current rating of 1kA (8/20µs), it can handle high-energy surges.

 

This GDT features very low capacitance (<1 pF at 1 MHz), making it suitable for high-speed data line protection without signal degradation. It has a glow voltage of approximately 70V at 10mA and an arc voltage of about 10V above 1A. The DC holdover voltage is 135V (network applied per ITU-T K.12) with a holdover time less than 150ms.

 

The device is housed in a 2-SMD cylinder square end package and is rated for surface mount assembly. It operates over a temperature range of -40°C to 90°C and is RoHS3 compliant. The GDT is designed to operate with Bourns TBU® devices for coordinated overcurrent protection.

 

Service life ratings include 2 operations at 1kA 8/20µs, 50 operations at 100A 10/1000µs, and 20 operations at 500A 2/10µs, among others. It is UL recognized and meets ITU-T K.12, IEEE C62.31, and IEC 61643-311 standards.

2031-42T-SM-RPLF Quick Information

Product Type: Gas Discharge Tube (GDT)
Series: 2031-xxT-SM
Canonical Name: Bourns 2031-42T-SM-RPLF Gas Discharge Tube, 2-Pole, 360V Min DC Sparkover, 1kA Impulse, Surface Mount
Subcategory: 2-Pole GDT

2031-42T-SM-RPLF Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

2031-42T-SM-RPLF Features

  • 2-pole surface mount gas discharge tube.
  • 360V minimum DC sparkover voltage.
  • 1kA impulse discharge current rating.
  • Low capacitance (<1 pF) for high-speed circuits.
  • RoHS3 compliant and UL recognized.

2031-42T-SM-RPLF Applications

  • Overvoltage protection in telecom equipment.
  • Surge protection for data lines and signals.
  • Used in industrial control and automation systems.
  • Protection for customer premises equipment.

2031-42T-SM-RPLF FAQs

7 frequently asked questions generated from this part’s specifications.
What is the typical DC sparkover voltage of the Bourns 2031-42T-SM-RPLF?

The typical DC sparkover voltage is 420V at 100 V/s.

What is the minimum DC sparkover voltage throughout service life?

The minimum DC sparkover voltage is 360V.

What is the impulse discharge current rating of this GDT?

The impulse discharge current is 1000A (1kA) for an 8/20 µs waveform.

What package and mounting type does the 2031-42T-SM-RPLF use?

It comes in a 2-SMD Cylinder Square End package and is surface mount.

What is the operating temperature range of this GDT?

The operating temperature range is -40°C to 90°C.

Is the Bourns 2031-42T-SM-RPLF RoHS compliant?

Yes, it is RoHS3 compliant as stated in the datasheet.

What is the capacitance of this GDT at 1 MHz?

The capacitance is less than 1 pF at 1 MHz.

Home