2027-60-SM-RPLF The Bourns 2027-60-SM-RPLF is a 600V surface mount gas discharge tube (GDT) with a 10kA impulse discharge current rating. It offers a low capacitance of <1 pF and is UL recognized.
Mfr Part #:

2027-60-SM-RPLF

Available from 1 distributors
Mfr Name: Bourns
Bourns
The Bourns 2027-60-SM-RPLF is a 600V surface mount gas discharge tube (GDT) with a 10kA impulse discharge current rating. It offers a low capacitance of <1 pF and is UL recognized.
Total Stock: 100 pcs

2027-60-SM-RPLF Available from 1 distributor

Authorised
Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
100 pcs
100 pcs On Request 1 On Request On Request On Request On Request On Request

2027-60-SM-RPLF Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Arc Voltage
Capacitance
DC Holdover Voltage
DC Sparkover Voltage
Diameter
Fail Short
Fail Short Mode
Glow Voltage
Glow-Arc Transition Current
Impulse Discharge Current (8
Impulse Discharge Current (8/20 µs) - 1 operation
Impulse Discharge Current (8/20 µs) - 10 operations
Impulse Sparkover Voltage (100 V/µs)
Impulse Sparkover Voltage (1000 V/µs)
Insulation Resistance
Length
Mounting Type
Number of Poles
Prop 65
Tape & Reel
Tolerance
UL Recognized
Voltage

2027-60-SM-RPLF Description

Short technical summary and product information.

The Bourns 2027-60-SM-RPLF is a precision gas discharge tube (GDT) surge protector from the 2027-SM series. It is a 2-electrode surface mount device designed for economical assembly and high surge current handling. The DC sparkover voltage is 600 V with a ±15% tolerance.

 

This GDT features an impulse sparkover voltage of 850 V at 100 V/µs and 1100 V at 1000 V/µs. It can withstand a single 8/20 µs impulse discharge current of 25000 A and a minimum of 10 operations at 10000 A. The glow voltage is approximately 70 V at 10 mA and the arc voltage is about 10 V at above 1 A, with a glow-arc transition current of less than 0.5 A.

 

The device offers very low capacitance of less than 1 pF at 1 MHz and high insulation resistance greater than 10¹⁰ Ω at 100 V. It comes in a compact 2-SMD cylinder square end package measuring 8 mm in diameter and 6 mm in length. It is compatible with pick and place assembly systems and is ideal for telecommunications, commercial, and industrial applications. The part is RoHS3 compliant and UL recognized.

2027-60-SM-RPLF Quick Information

Product Type: Gas Discharge Tube
Series: 2027-SM
Canonical Name: 2027-60-SM-RPLF Bourns 600V 10kA 2 Pole Gas Discharge Tube
Subcategory: 2-Electrode Surface Mount GDT

2027-60-SM-RPLF Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected
Lead Free: Yes

2027-60-SM-RPLF Features

  • Rated for 600 V DC sparkover voltage.
  • Handles 10 kA impulse discharge current.
  • Very low capacitance under 1 pF.
  • Surface mount 8 mm x 6 mm package.
  • UL recognized and RoHS3 compliant.

2027-60-SM-RPLF Applications

  • Used for telecom line circuit protection.
  • Protects industrial control equipment.
  • Ideal for commercial surge protection circuits.
  • Applicable in data line surge suppression.

2027-60-SM-RPLF FAQs

6 frequently asked questions generated from this part’s specifications.
What is the DC sparkover voltage of the 2027-60-SM-RPLF?

The DC sparkover voltage is 600 V with a tolerance of ±15%.

What is the impulse discharge current rating?

For a single 8/20 µs impulse, the rating is 25000 A. For 10 or more operations, it is 10000 A.

What is the package type and size?

The package is 2-SMD Cylinder Square End, surface mount, with an 8 mm diameter and 6 mm length.

Is this component RoHS compliant?

Yes, it is RoHS3 compliant (Directive 2015/863).

What is the capacitance of this GDT?

The capacitance is less than 1 pF at 1 MHz.

Does this GDT fail short?

No, the fail short mode is not applicable; the device does not fail short.