The Bourns 2027-25-SMLF is a gas discharge tube (GDT) surge protection device designed for surface mount assembly. It features a DC sparkover voltage of 250V with ±15% tolerance and a high impulse discharge current rating of 10kA (8/20 µs waveform).
The device offers low capacitance (<1 pF at 1 MHz) and stable breakdown characteristics throughout its life, making it suitable for protecting sensitive circuits in telecommunications and industrial applications. The 2-pole configuration and 2-SMD cylinder square end package (8 mm diameter, 6 mm long) enable compact PCB layouts.
The 2027-25-SMLF is compatible with pick-and-place assembly and is RoHS3 compliant. It carries UL recognition and a Proposition 65 warning for cancer and reproductive harm.
The DC sparkover voltage is 250 V with a tolerance of ±15%.
The impulse discharge current is 10000 A (10 kA) for an 8/20 µs waveform.
The datasheet indicates compliance with RoHS Directive 2015/863, marked as RoHS3 compliant.
The package is 2-SMD Cylinder Square End, measuring 8 mm diameter by 6 mm long, suitable for surface mount.
Typical impulse sparkover for the 2027-25-SM model is 450 V at 100 V/µs and 675 V at 1000 V/µs.