This E-T-A 2-6500-P10-11A is a bimetal-operated, single-pole thermal circuit breaker with automatic reset actuation. It is designed for motor protection in applications such as motors, transformers, and extra-low voltage wiring.
Key electrical specifications include a voltage rating of 250V AC (50/60 Hz) and 28V DC, with a current rating of 11A. The breaker offers an interrupting capacity of 8 x IN and a typical life of 100,000 operations at 2 x IN.
Designed for panel mounting, this circuit breaker has a housing degree of protection of IP30 and a terminal area of IP00. It operates within an ambient temperature range of -10°C to +60°C. The breaker has undergone vibration, shock, corrosion, and humidity testing according to IEC standards.
Approvals include CSA C22.2 No 235 and UL1077, ensuring reliability in various applications. The internal resistance varies depending on the current rating, with specific values provided for different ampere ratings.
250V AC or 28V DC.
-10°C to +60°C.
The breaker automatically resets after a fault clears, typically taking between 30 and 70 seconds to cool down and re-close.
It uses QC .250 (6.3x0.8mm) blade terminals for connection.
It is approved under UL1077, UL 244A, and CSA C22.2 No 235 standards.
The unit is rated for 100,000 operations at twice its nominal current.