| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Ingress Protection | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature Range | |
| Voltage Rating |
The Mechanical Products Series 18 is a line of superior circuit protection devices, including the 1810-E1-1-3T-0700-13 thermal circuit breaker. This specific model is rated for 70A and operates at a maximum voltage of 120VAC and 32VDC.
Designed for reliability, this circuit breaker meets stringent requirements from organizations like UL, ABYC, and SAE. It features UL 1500 ignition protection, making it suitable for environments where flammable vapors may be present. The breaker is also built to withstand harsh conditions, conforming to Mil-STD-202 for corrosion, humidity, shock, and vibration resistance, as well as SAE J1428 for weatherproof requirements.
With a thermal trip mechanism, the 1810-E1-1-3T-0700-13 offers clearly specified protection. It has a resettable overload capacity of 10x rated value and an inrush capacity of 35X rated capacity for 1/2 cycle. The operating temperature range is from -54°C to 60°C (-65°F to 140°F).
This circuit breaker is designed for chassis mounting and features a push-to-reset actuator. It is CE Marked and made in the USA.
The maximum operating voltage is 120VAC or 32VDC.
Supplied in a box.
-54°C to 60°C (-65°F to 140°F).
3000A at 32VDC.
Thermal circuit breaker.
Chassis mount with push-to-reset actuator.
Yes, conforms to UL 1500 ignition protection and USCG Title 33 CFR 183.410(a).