| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 1658-G41-09-P10-055800-30A is a single-pole thermal overcurrent circuit breaker from the 1658 series. It offers a robust design with a manual reset and a cycling trip-free mechanism, meeting international requirements.
This circuit breaker is rated for a maximum of 30A and operates at 240V AC or 28V DC. It features blade terminals for connection and a panel mount design for easy integration into systems. The device is approved by UL, CSA, and VDE.
Typical applications for this thermal circuit breaker include battery chargers, consumer products, power supplies, and motors. Its compact and lightweight design makes it suitable for various electronic and electrical equipment where reliable overcurrent protection is essential.
The circuit breaker is rated for 240VAC and 28VDC.
The current rating is 30A.
The operating temperature range is -20°C to +60°C, with a maximum of +40°C for currents up to 7A.
The interrupting capacity Icn is 200A for current ratings 8-30A. For UL 1077/EN 60934 PC1, it is 2000A at 240VAC (5-16A) and 120VAC (17-30A), and 2500A at 32VDC (5-30A).
The breaker is panel mounted with blade terminals (A6.3-0.8, QC .250).
The actuator type is push to reset.
The operating area has IP40 protection, and the terminal area has IP00 protection.