| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 1658-G41-08-P10-8A is a cost-effective thermal overcurrent circuit breaker designed to meet international requirements. This single-pole breaker features a push-to-reset actuator and a panel mount design.
With a voltage rating of 240 VAC and 28 VDC, and a current rating of 8A, this circuit breaker is suitable for various applications. It boasts an interrupting capacity of 2000A at AC and DC voltages. The operating temperature range is -20°C to +60°C, with a maximum of +40°C for currents 8A and above.
Key electrical specifications include a dielectric strength of 3000V AC and an insulation resistance greater than 100 MΩ at 500V DC. The breaker is designed with reinforced insulation in the operating area and offers an ingress protection rating of IP40 for the operating area and IP00 for the terminal area.
Typical applications for the 1658 series include battery chargers, consumer products, power supplies, and motors. The unit is compact and lightweight, weighing approximately 16g. It is approved by UL, CSA, VDE, and EN 60934 (IEC 60934).
The voltage rating is 240 VAC and 28 VDC.
The current rating is 8A.
It has a push-to-reset actuator.
It is designed for panel mounting.
The operating temperature range is -20°C to +60°C.
The interrupting capacity is 2000A.