The E-T-A 1658-G41-01-P10-10A is a single-pole, thermal overcurrent circuit breaker designed for cost-effective international requirements. It features a manual reset, cycling trip-free mechanism and is extremely small and lightweight.
This circuit breaker has a current rating of 10A and can handle up to 240VAC or 28VDC. It boasts a high interrupting capacity of 2,000A under various conditions and an insulation resistance greater than 100 MΩ. The operating area has an IP40 degree of protection, while the terminal area is IP00.
Environmental testing includes vibration resistance up to 8g, shock resistance of 30g, 96-hour salt mist corrosion resistance, and 240-hour humidity resistance. It is approved by VDE, UL, and CSA, meeting international standards.
Typical applications include battery chargers, consumer products, power supplies, and motors. The panel mount design with a push-to-reset actuator makes it suitable for various integration needs.
240V AC and 28V DC.
10A nominal, with a range of 5 to 30A.
Thermal circuit breaker.
Panel mount.
-20 to +60°C, with derating above 8A.
VDE (EN 60934) and UL/CSA.
200A (Icn) and up to 2,000A under specific conditions.