| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 1658-G41-00-S83-25A is a single-pole thermal circuit breaker designed for overcurrent protection. It offers a current rating of 25A and a voltage rating of 240V AC or 28V DC.
This circuit breaker features a manual push-to-reset actuator and a panel mount design for easy integration into systems. It has an interrupting capacity of 200A at its rated voltage and current.
Key specifications include an operating temperature range of -20°C to +60°C, an IP40 degree of protection for the operating area, and a typical life of 1,000 operations at 2x In. The device is built to meet international requirements with no exposed current-carrying metal parts except for terminals.
Typical applications for this series include battery chargers, consumer products, power supplies, and motors. It is approved by UL, CSA, VDE, and EN 60934 standards.
The breaker is rated for 240V AC and 28V DC.
It is rated for 25A continuous current, with a range of 5-30A depending on configuration.
The interrupting capacity is 200A for most configurations, and up to 2000A for 5-16A at 240V AC, 18-30A at 120V AC, and 5-30A at 28V DC.
The breaker operates from -20°C to +60°C, with a maximum of +40°C for currents below 8A.
It has a push-to-reset actuator.
The breaker is panel mounted.