| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| SVHC Present | |
| Voltage Rating |
This E-T-A 1658-G41-00-S80-055843-10A is a single-pole thermal circuit breaker with a current rating of 10A. It is designed for panel mounting and features a manual reset with a cycling trip-free mechanism.
The breaker operates at AC voltages up to 240V and DC voltages up to 28V. It has an interrupting capacity of 200A (Icn) and 2,000A (UL). The device is built to meet international requirements, with no exposed metal parts that could become current-carrying except for the terminals.
Key technical specifications include an ambient temperature range of -20°C to +60°C, an IP40 degree of protection for the operating area, and an IP00 rating for the terminal area. It also meets various environmental and mechanical stress tests, including vibration, shock, corrosion, and humidity resistance.
Typical applications for this circuit breaker include battery chargers, consumer products, power supplies, and motors. It is approved by UL, CSA, and VDE.
10A.
240VAC (50/60 Hz) and 28VDC.
1 pole.
Push to Reset.
-20°C to +60°C.
200A (Icn) per EN 60934, and 2,000A per UL 1077.
Panel Mount.