| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 1658-G21-02-P10-12A is a thermal overcurrent circuit breaker designed for cost-effectiveness and international requirements. It offers a manual reset with a cycling trip-free mechanism and no exposed current-carrying metal parts.
Key electrical specifications include a voltage rating of 240V AC and 28V DC, with a current rating of 12A. The interrupting capacity is rated at 1000A for 5-16A AC 240V and 2000A for 5-30A AC 125V or DC 32V. The typical life is 1,000 operations at 2x IN.
This circuit breaker operates within an ambient temperature range of -20°C to +60°C. It has a degree of protection of IP40 in the operating area and IP00 at the terminals. The device is designed for panel mounting and features a push-to-reset actuator.
Typical applications include battery chargers, consumer products, power supplies, and motors. It meets international standards including UL, CSA, VDE, and EN 60934 (IEC 60934).
The current rating is 12A.
The AC voltage rating is 240V.
The DC voltage rating is 28V.
The operating temperature range is -20°C to +60°C.
It is a panel mount type.
The RoHS status is RoHS3 Compliant.