| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 1658-F01-00-P13-D01-6A is a single-pole thermal circuit breaker with a panel mount design. It offers a current rating of 6A and is suitable for AC applications up to 240V and DC applications up to 28V.
This circuit breaker utilizes a manual reset, cycling trip-free mechanism and is approved to EN 60934 (IEC 60934) standards. It features a push-to-reset actuator and blade terminals.
Typical applications for this series include battery chargers, consumer products, power supplies, and motors. The device is designed with no exposed metal parts that could become current-carrying, except for the terminals, meeting R-type TO CBE requirements.
Key technical specifications include an interrupting capacity of 2000A at AC 240V and DC 28V, an ambient operating temperature range of -20°C to +60°C, and a degree of protection of IP40 for the operating area.
Rated for 240VAC and 28VDC.
-20°C to +60°C (derated to 40°C at currents above 7A).
2000A at 240VAC and 2000A at 28VDC.
1 pole.
IP40 for operating area, IP00 for terminal area.
Shock: 30g (11ms) per IEC 60068-2-27. Vibration: 8g (57-500Hz) with ±0.61mm (10-57Hz) per IEC 60068-2-6.
3000V AC in operating area per IEC 60664.