| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Ambient Temperature | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The E-T-A 1658-F01-00-P10-6A is a single-pole thermal circuit breaker designed for overcurrent protection. It operates with a voltage rating of 240 VAC or 28 VDC and handles current ratings from 5 to 30 A, with this specific model rated at 6A.
This circuit breaker features a manual reset with a cycling trip-free mechanism and a push-to-reset actuator. It is designed for panel mounting and offers a degree of protection of IP40 in the operating area and IP00 at the terminals.
Key specifications include an interrupting capacity of 2000 A at various voltage/current combinations, a typical life of 1,000 operations at 2x I N, and an operating ambient temperature range of -20 to +60 °C. The device is compact and lightweight, weighing approximately 16g.
Typical applications for the 1658 series include battery chargers, consumer products, power supplies, and motors. It meets international requirements and is approved by UL, CSA, VDE, and EN 60934 (IEC 60934).
240 VAC and 28 VDC.
-20 to +60 °C.
2000 A at 240 VAC (5-16 A) and 120 VAC (18-30 A), and 2000 A at 28 VDC (5-30 A). Also 200 A nominal.
Push to reset.
1.
IP40 for operating area, IP00 for terminal area.
Panel mount.