This E-T-A 1658-A21-00-P10-13A is a single-pole thermal circuit breaker with a current rating of 13A. It is designed for panel mounting and offers automatic reset functionality.
The breaker is rated for 240 VAC and 28 VDC. It operates within an ambient temperature range of -20°C to 60°C, with a reduced maximum ambient temperature of 40°C for current ratings up to 7A. The interrupting capacity (Icn) is 200A, and the interrupting capacity (I N U N) is 2000A at AC 120V and DC 28V.
Typical applications for this series include battery chargers, consumer products, power supplies, and motors. The device has an operating area protection degree of IP40 and a terminal area protection degree of IP00. Its mass is approximately 16g.
Approvals include VDE (EN 60934) for AC 240V/DC 28V and 5-25A, UL for AC 240V/5-16A and AC 120V/18-30A, and DC 32V/5-30A for specific models.
240VAC and 28VDC.
13A.
Thermal.
-20 to 60°C.
Yes, the actuator type is automatic reset.
Panel mount.
200A Icn, and 2000A at 120VAC or 28VDC under UL 1077/EN 60934 conditions.